| Step |
Look for: |
Meter postiton |
Procedure |
| 1 |
(max) |
A (MOD-1) |
Tune T101 for max reading on lowest freq. |
| 2 |
(max) |
B (MOD-2) |
Tune T102 & then T103 for max reading on lowest freq. |
| 3 |
(min) |
C (MULT-1) |
Tune T104 for a dip in meter reading. |
| 4 |
... |
D (MULT-2) |
Tune T105 for max meter reading, & re-adjust T104 for
max meter reading. Then tune T106 for a dip in meter reading. |
| 5 |
... |
F (MULT-3) |
Tune T107 for max meter reading, & re-adjust T106 for
max meter reading. Then tune T108 for a dip in meter reading & T109
for a max meter reading. |
| 6 |
(max) |
G (AMPL-1) |
Tune T110 for max meter reading, and then re-adjust T108
& T109 for max meter reading. |
| 7 |
(max) |
D(AMP-1 DRIVE) |
Move the black metering plug to power amp and tune T111
and then T112 for max meter reading. |
| 8 |
(max) |
G (AMP-1) |
Move black metering plug back to the exciter and re-adjust
T108, T109, & T110 for max meter reading. |
| 9 |
(max) |
D(AMP-1 DRIVE) |
Move black metering plug to power amp.(on P.A.) re-adjust
T111 and T112 for max meter reading. |
| 10 |
You're done with exciter --- now adjust power
setting on P.A. to desired output. |